| BRACKISH WATER ELEMENTS > 2540-HM1-CPA2 | 8040-HM1-CPA2 | |||||
|
Brackish Water Elements |
|||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||
| Membrane Element 4040- HM1- CPA2 | |||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||
| Performance | Permeate Flow Salt Rejection-nominal | 2200 gpd (8.33 m3/d) 99.5% |
|||||||||||||||||||||||||||||||
| Type | Configuration: Membrane Polymer: Nominal Membrane Area: |
Spiral wound Composite Polyamide 85 ft2 |
|||||||||||||||||||||||||||||||
| Operating Limits & Application Data |
Maximum Applied Pressure: Maximum Chlorine Concentration: Maximum Operating Temperature: Feedwater pH Range: Maximum Feedwater Turbidity: Maximum Feedwater SDI (15 mins) Maximum Feed Flow: Minimum Ratio of Concentrate to Permeate Flow for any Element: Maximum Pressure Drop for each Element: |
600 psig (4.16 MPa) < 0.1 ppm 113 °F (45 °C) 3.0 - 10.0 1.0 NTU 4.0 16 GPM (3.6 m3/h) 5:1 10 psi |
|||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||
|
Dimensions | |||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||
| A | inches | (mm) | B | inches | (mm) | |
| 40.00 | (1016) | 3.95 | (100.3) | |||
| C | inches | (mm) | D | weight | lbs. (kg) | |
| 0.75 | (19.1) | 8 | (3.6) |
![]() |
||
| Test conditions : | The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions : 1500 ppm NaCl solution,applied pressure- 15.5 kg/ sq.cm2 (225 psig), operating temperature- 77 °F (25 °C) ,15% permeate recovery-15% and pH range 6.5 - 7.0 |
|
| Note: | Minimum permeate flow for individual elements may vary to + or - 15 percent of nominal. All membrane elements are supplied with a brine seal. Elements are vacuum sealed in a polyethylene bag containing a 1.5 % sodium bisulfite solution and 20% propylene glycol solution, and then packaged in a cardboard box. | |

| Top |