Product Contact Us Site Map Home

Industrial Reverse Osmosis Plants
Packaged Reverse Osmosis Systems (INDRO)- 30 LPH TO 3000 LPH

 

MODEL INDRO 251 INDRO 252 INDRO 401 INDRO 402 INDRO 403 INDRO 404 INDRO 405 INDRO 801 INDRO 802
Flow rate - Litre/ Hour. 30 60 200 400 600 800 1000 2000 3000
Inlet pressure- Kg/cm2 (minimum) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
Maximum Feed water TDS - PPM 1500 1500 1500 2500 2500 2500 2500 2500 2500
Average Rejection of TDS - % 90 90 90 90 90 90 90 90 90
Average Recovery - % 30 30 30 30 30 30 30 30-65 30-65
Pump / Motor 316 stainless steel multistage pump along TEFC motor
Input Voltage- V , 50 Hz 220/230 220/230 220/230 415 415 415 415 415 415


INDRO - Standard Reverse Osmosis System : An economical way to obtain pure water from brackish water.

PACKAGED REVERSE OSMOSIS SYSTEMS
FEATURES:

  • Product flow rate 1.5 - 60 m3/h .

  • Salt rejection ranges from 90 to 98 % depending upon feed water composition

  • Product recovery ranges from 50 to 80 % depending upon feed water composition.

  • Electrical 415V, 3 ph, 50 Hz

  • Concentrate discharge directed to drain at 'O' psi


  • ADVANTAGES:

  • Modular design - capacity can be increased to suit requirements.

  • Fully assembled skid, tested prior to shipment, ease of installation and beneficial use.

  • Non- corrosive low pressure piping - virtually maintenance free

  • Low on energy consumption

  • User friendly unit - does not require continuous monitoring


  • APPLICATIONS:

  • Ultrapure water for electronic industries.

  • Ultrapure water for pharmaceutical industries

  • Process water for manufacturing plants

  • Beverage and food processing industry

  • Drinking water

  • Waste water

  • Mineral water

  • Bio-technology

  • SPECIFICATIONS:

  • Cartridge pre-filter

  • FRP pressure vessels

  • Spiral wound membrane elements of polyamide type

  • 316 stainless steel high pressure piping

  • Low feed pressure switch for pump protection

  • Motor starter with disconnect switch

  • Motor contactor with thermal overload protection

  • Sample valves for feed, product and concentrate.

  • Concentrate check valve

  • Product check valve

  • Automatic feed shut-off valve

  • Cleaning connections

  • Full control panel instrumentation

  • Pump discharge pressure indicator

  • Feed and concentrate pressure indicator

  • Product and concentrate flow meters

  • Conductivity meter

  • Power on light

  • Fault alarm

  • Post shutdown system flush
  • FEED WATER REQUIREMENTS:

  • Temperature 400C maximum

  • Pressure 2-3 Kg/cm2 (30-45 psi)

  • Salinity: up to 5000 ppm Total Dissolved Solids     (TDS). For higher value contact us for advice.

  • Silt density index (SDI) < 4.0

  • Oil and grease - absent

  • Iron & manganese 0.1 ppm, maximum (total)

  • pH 4-10


  • OPTIONS:

  • pH monitor/controller

  • Chemical feed systems

  • Pre-treatment system

  • Cleaning system

  • Post treatment system

  • Top