Product Contact Us Site Map Home
LOW PRESSURE ELEMENTS > 2540-HM1-LPE | 4040-HM1-LPE | 8040-HM1-LPE
Membrane Element      1812-HM1-LPE
PerformancePermeate Flow
Salt Rejection-nominal
75 gpd (0.28 m3/d)
99.0%
TypeConfiguration
Membrane Polymer
Spiral wound
Composite Polyamide
Operating Limits & Application Data Maximum Applied Pressure
Maximum Chlorine Concentration
Maximum Operating Temperature
Feedwater pH Range
Maximum Feedwater Turbidity
Maximum Feedwater SDI (15 mins)
Minimum Ratio of Concentrate to
Permeate Flow for any Element
Maximum Pressure Drop for each Element
300 psig (2.1 MPa)
< 0.1 PPM
113 °F (45 °C)
3.0 - 10.0
1.0 NTU
4.0

5:1
10 psi.
Dimensions:
Diagram
Ainches(mm) Binches(mm)
 12.00 (305)  1.8 (46)
Cinches(mm) Dweight lbs. (kg)
 0.75 (19.1)  1.0(0.5)


Test Conditions:

The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions : 500 PPM NaCl solution,applied pressure- 6.88 kg/ sq.cm2 (100 psi), operating temperature- 77 °F (25 °C) ,15% permeate recovery-15% and pH range 6.5 - 7.0 .

Note:

Minimum permeate flow for individual elements may vary to + or - 15 percent of nominal. All membrane elements are supplied with a brine seal. Elements are vacuum sealed in a polyethylene bag containing a 1.5 % sodium bisulfite solution and 20% propylene glycol solution, and then packaged in a cardboard box.