Product Contact Us Site Map Home
SEA WATER ELEMENTS > SWC1-2540 | SWC1-4040 | SWC2-4040 | SWC1-8040 | SWC3-8040
Hydranautics
Membrane Element      SWC2-8040
 
 Performance
 
Permeate Flow
Salt Rejection-Minimum
 
6200 gpd (23.5 m3/d)
99%
 
 Type
 
Configuration
Membrane Polymer
Nominal Membrane Area
 
 
Spiral Wound
Composite Polyamide
315 ft 2
 
 Application Data
 
Maximum Applied Pressure
Maximum Chlorine Concentration
Maximum Operating Temperature
Feedwater pH Range
Maximum Feedwater Turbidity
Maximum Feedwater SDI (15 mins)
Maximum Feed Flow
Minimum Ratio of Concentrate to
Permeate Flow for any Element
Maximum Pressure Drop for each Element
 
For operation outside these conditions,
please contact us.
 
 
1200 psig (8.27 MPa)
< 0.1 ppm
113 °F (45 °C)
3.0 - 10.0
1.0 NTU
5.0
75 GPM (17 m3/h)
 
5:1
10 psi.
 
 Test Conditions

 
The stated performance is initial (data taken after 30 minutes of operation),
based on the following conditions :
 
32000 PPM NaCl Solution,
800 psi (5.5MPa) Applied Pressure
77 °F (25 °C) Operating Temperature
10% Permeate Recovery
6.5 - 7.0 pH Range.
 


Diagram
Ainches(mm)   Binches(mm)   Cinches(mm)   Dweight lbs. (kg)
 40.00 (1016)    7.95(201.9)    1.50(38.1)     36  (16.4)


Note:

Minimum permeate flow for individual elements 15 percent below listed flow. All membrane elements are supplied with a brine seal rings. Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box.
 

Top